The yield hasn't dropped, but each wafer has more defects - how to set the threshold for the count based Control Chart?
In recent batches, the number of defects has been slowly increasing, and the yield is still within the specifications. We are concerned that this may be a systemic change. I would like to inquire about the grouping method and alarm boundaries for count based Control Charts.
Discussion 2
Please Sign In to join the discussion
Are defects calculated by piece or by area? If the unit area is not consistent, using the u diagram is more reliable than the c diagram. Align the aperture first and then set the threshold.
We have also encountered a similar situation where a single point does not exceed the limit but multiple points are on the same side continuously. It is recommended to first create a C-chart by batch or machine grouping, and then open the discrimination rule for 7 consecutive points on the same side to see.